Roorkee, Uttarakhand India +91-8979900000 sales@recordtek.com Serving your measurement needs for decades

Solution Integrator

Leading Strain Gauge

Certified


Load Cells

Tension / Compression Load Cell

The TCLB-NA Tension/Compression Universal Load Cell is a low capacity load cell. It can be used for high precision measurement because the internal structure uses both ends fixation beam for the strain sensing element.
Protection ratings : TCLB-50NA IP 40 equivalent TCLB-100NA/-200NA IP 42 equivalent
Features
  • Low-capacity, High precision
  • Small, Light weight
📄 Data Sheet >

Specifications

TYPE TCLB-50NA TCLB-100NA TCLB-200NA
Capacity 50N 100N 200N
Rated Output 1.5mV/V (3000×10-6 strain) ±0.5%
Non-linearity 0.1%RO
Hysteresis 0.1%RO
Natural Frequency 0.9kHz 1.4kHz 2kHz
Temperature effect on zero 0.01%RO/°C
Temperature effect on span 0.01%/°C
Compensated temperature range -10 ~ +60°C
Allowable temperature range -20 ~ +70°C
Overload 150%
Input/Output resistance 350Ω±2%
Recommended exciting voltage 6V or less
Allowable exciting voltage 15V
Zero balance 5%RO
Weight 0.45kg 0.9kg
Input/Output cable : φ9mm 0.5mm2 4-core shielded chloroprene cable 5m
The TCLA-NB Tension/Compression Universal Load Cell comes to much smaller and lightweight than conventional TCLA-NA. High capacity ranges of 10kN and 20kN are added on the line. It is hermetically sealed, enabling highly precise and consistent measurement.
Protection ratings : IP 67 equivalent
Features
  • Small, Lightweight
  • Tension and compression
  • Hermetically sealed structure
  • Stable measurement
  • Easy handling
📄 Data Sheet >

Specifications

TYPE TCLA-500NB TCLA-1KNB TCLA-2KNB TCLA-5KNB TCLA-10KNB TCLA-20KNB
Capacity 500N 1kN 2kN 5kN 10kN 20kN
Rated Output 1.5mV/V (3000×10-6 strain) ±2% 1.5mV/V (3000×10-6 strain) ±1% 2.0mV/V (4000×10-6 strain) ±1%
Non-linearity 0.3%RO 0.2%RO
Hysteresis 0.1%RO
Natural Frequency 4.5kHz 6.7kHz 8.5kHz 13kHz 17kHz 16kHz
Temperature effect on zero 0.01%RO/°C
Temperature effect on span 0.01%/°C
Compensated temperature range -10 ~ +60°C
Allowable temperature range -20 ~ +70°C
Overload 150% 120%
Input/Output resistance 350Ω±2%
Recommended exciting voltage 6V or less
Allowable exciting voltage 15V
Zero balance 5%RO
Weight 0.6kg 0.7kg
Input/Output cable : φ6mm 0.35mm2 4-core shielded chloroprene cable 5m
The TCLK-NA Tension/Compression Universal Load Cell has a low profile construction that serves to save installation space.
Protection ratings : IP 67 equivalent
Features
  • Hermetically sealed structure
  • Stable measurement
  • Small, Lightweight, Low height
  • Small deflection
  • Suitable for testing machines
Data Sheet >

Specifications

TYPE TCLK-5KNA TCLK-10KNA TCLK-20KNA TCLK-50KNA
Capacity 5kN 10kN 20kN 50kN
Rated Output 2mV/V (4000×10-6 strain) ±1%
Non-linearity 0.1%RO
Hysteresis 0.1%RO
Natural Frequency 18kHz 17kHz 17kHz 14kHz
Temperature effect on zero 0.01%RO/°C
Temperature effect on span 0.01%/°C
Compensated temperature range -10 ~ +60°C
Allowable temperature range -20 ~ +70°C
Overload 150%
Input/Output resistance 350Ω±2%
Recommended exciting voltage 6V or less
Allowable exciting voltage 15V
Zero balance 5%RO
Weight 0.45kg 0.8kg 1.3kg 2.6kg
Input/Output cable : TCLK-5KNA  &nbsp φ3mm 0.05mm2 4-core shielded chloroprene cable 5m TCLK-10KNA~-50KNA     φ6mm 0.35mm2 4-core shielded chloroprene cable 5m
The TCLP-NB Tension/Compression Universal Load Cell is a load cell widely used in applications such as measuirng crane and jack loads because it offers excellent consistency. This load cell is available with built-in two isolated input / output on request.
Protection ratings : IP 65 equivalent
Features
  • Easy handling
  • Excellent stability
  • Many load ranges for selection according to purposes
Data Sheet >

Specifications

TYPE TCLP- 10KNB TCLP- 20KNB TCLP- 30KNB TCLP- 50KNB TCLP- 100KNB TCLP- 200KNB TCLP- 300KNB TCLP- 500KNB TCLP- 1MNB TCLP- 1.5MNB* TCLP- 2MNB
Capacity 10kN 20kN 30kN 50kN 100kN 200kN 300kN 500kN 1MN 1.5MN 2MN
Rated Output 1mV/V (2000×10-6 strain) ±0.5%
Non-linearity 0.1%RO 0.3%RO
Hysteresis 0.1%RO 0.3%RO
Natural Frequency 6.8kHz 7.9kHz 8.3kHz 10kHz 10kHz 7.7kHz 6.7kHz 5.3kHz 4kHz 3.1kHz 2.6kHz
Temperature effect on zero 0.01%RO/°C
Temperature effect on span 0.005%/°C
Compensated temperature range -10 ~ +60°C
Allowable temperature range -20 ~ +70°C
Overload 200%
Input/Output resistance 350Ω±1%
Recommended exciting voltage 10V or less
Allowable exciting voltage 20V
Zero balance 5%RO
Weight 1.5kg 1.5kg 2kg 2kg 2.5kg 5kg 8kg 15kg 50kg 85kg 110kg
Supplied cable : CT9-4N10/WP-STB (φ9mm 0.5mm2 4-core shielded chloroprene cable 10m)   *Made-to-order
The TCLU-NA Tension/Compression Universal Load Cell is an inert-gas encased load cell in a hermetically sealed package. It can take highly precise and consistent measurements over long periods of time, and is used primarily in applications such as measuring crane and jack loads. This load cell is available with built-in two isolated input / output on request .
Protection ratings : IP 65 equivalent
Features
  • High precision, High output
  • Excellent stability
  • Easy handling
Data Sheet >

Specifications

TYPE TCLU- 10KNA TCLU- 20KNA TCLU- 50KNA TCLU- 100KNA TCLU- 200KNA
Capacity 10kN 20kN 50kN 100kN 200kN
Rated Output 2mV/V (4000×10-6 strain) ±0.5%
Non-linearity 0.15%RO
Hysteresis 0.05%RO
Natural Frequency 4.8kHz 5.3kHz 6.0kHz 4.8kHz 2.4kHz
Temperature effect on zero 0.005%RO/°C
Temperature effect on span 0.005%/°C
Compensated temperature range -10 ~ +60°C
Allowable temperature range -30 ~ +80°C
Overload 150%
Input/Output resistance 350Ω±1%
Recommended exciting voltage 10V or less
Allowable exciting voltage 20V
Zero balance 5%RO
Weight 4kg 4kg 4kg 11kg 18kg
Input/Output cable : φ9mm 0.5mm2 4-core shielded chloroprene cable 5m
Accordion Content
Compared with TML ordinary Tension/Compression Universal Load Cells, the TCLN-NA is very small and light model. The Input/Output cable is as thin as 3mm in diameter for easiness to handle.
Protection ratings : IP 67 equivalent
Features
  • Airtight structure enabling stable measurement
  • Compact and lightweight, easy handling
Data Sheet >

Specifications

TYPE TCLN-500NA TCLN-1KNA TCLN-2KNA TCLN-5KNA
Capacity 500N 1kN 2kN 5kN
Rated Output 1mV/V (2000×10-6 strain) ±20%
Non-linearity 0.5%RO
Hysteresis 0.1%RO
Natural Frequency 10kHz 12kHz 14kHz 14kHz
Temperature effect on zero 0.05%RO/°C
Temperature effect on span 0.05%/°C
Compensated temperature range -10 ~ +60°C
Allowable temperature range -20 ~ +70°C
Overload 150%
Ultimate overload rating 200%
Input/Output resistance 350Ω±1%
Recommended exciting voltage 6V or less
Allowable exciting voltage 15V
Zero balance 10%RO
Weight 80g 80g 80g 140g
Input/Output cable : φ3mm 0.05mm2 4-core shielded chloroprene cable 5m

Request for Information